Water Cooled Chiller: Maximum Efficiency • Critical Process Stability • Heavy-Duty Reliability.
Engineered for large-scale cooling where precision and energy savings matter
Key Advantages
✅ 50% Higher Efficiency
COP up to 7.2 vs. air-cooled systems
✅ Stable Cooling
±1°C precision for manufacturing/labs
✅ High Ambient Performance
Unaffected by outdoor temperature swings
| Model | LWC025 | LWC030 | LWC035 | LWC040 | LWC045 | LWC050 | LWC060 | ||
| Cooling capacity(kw) 50hz | 78.5 | 95.5 | 108.6 | 125.4 | 140.1 | 155.6 | 186.8 | ||
| Cooling capacity (kcal/h) 50hz | 67,510 | 82,130 | 93,396 | 107,844 | 120,486 | 133,816 | 160,648 | ||
| Cooling capacity(kw) 60hz | 94.1 | 114.5 | 130.3 | 150.4 | 168.1 | 186.7 | 224.1 | ||
| Cooling capacity (kcal/h) 60hz | 80,926 | 98,470 | 112,058 | 129,344 | 144,566 | 160,562 | 192,726 | ||
| Input power(kw) | 20.2 | 24.6 | 28.3 | 32.2 | 36.5 | 40.3 | 48.5 | ||
| Chilled fluid flow (m3/h) 50hz | 13.5 | 16.4 | 18.8 | 21.4 | 24.1 | 26.7 | 31.9 | ||
| Chilled fluid flow (m3/h) 60hz | 16.3 | 19.6 | 22.6 | 25.5 | 28.9 | 31.9 | 38.4 | ||
| Cooling fluid flow (m3/h) 50hz | 17.3 | 20.6 | 24.1 | 27.4 | 30.9 | 34.2 | 40.9 | ||
| Cooling fluid flow (m3/h) 60hz | 20.7 | 24.7 | 28.8 | 32.9 | 37.1 | 41 | 49.1 | ||
| Powe supply voltage | 3ph-380v-50hz(200v/220v/415v 50hz/60hz) | ||||||||
| Compressor Type | Hermtic scroll type(piston) | ||||||||
| Compressor Starting method | Sequential start | ||||||||
| Compressor power(kw) | 18.8 | 22.5 | 26.3 | 30 | 33.8 | 37.5 | 45 | ||
| Refrigerant Type | R22(R407c/R410a/R134a) | ||||||||
| Refrigerant Control mode | Expansion valve | ||||||||
| Refrigerant Filling amount | 12.5 | 15 | 17.5 | 20.2 | 22.5 | 25 | 30 | ||
| Evaporator Type | Shell and tube(Water tank with coil) | ||||||||
| Evaporator Pipe (B) | PT2-1/2″ | PT3″ | |||||||
| Condenser Type | Shell and tube | ||||||||
| Condenser Pipe (B) | PT2-1/2″ | PT3″ | |||||||
| Tank volume (L) | 180 | 220 | 220 | 220 | 280 | 280 | 280 | ||
| Water pump power (kw) | 1.5 | 2.2 | 2.2 | 2.2 | 3 | 3 | 3 | ||
| Protective device | Compressor overheating, over current, high and low pressure, over temperature, flow switch, phase sequence, phase-missing, exhaust overheating, anti-freezing, etc. | ||||||||
| Dimension L (mm) | 1700 | 2100 | 2100 | 2100 | 2100 | 2100 | 2400 | ||
| Dimension W (mm) | 900 | 900 | 900 | 1100 | 1100 | 1100 | 1100 | ||
| Dimension H (mm) | 1330 | 1380 | 1380 | 1430 | 1450 | 1450 | 1450 | ||
| Weight (kg) | 680 | 890 | 1000 | 1090 | 1300 | 1430 | 1600 | ||
Maximized Energy Efficiency: Water-cooled condensation achieves higher COP (Coefficient of Performance) than air-cooled alternatives, significantly lowering energy costs.
Scroll Compressor Reliability: Durable, low-vibration compressors ensure quiet operation, extended lifespan, and minimal maintenance.
High Capacity & Stability: Designed for heavy, continuous cooling loads with precise temperature control (±0.5°C typical).
Space-Saving Design: Compact footprint vs. equivalent air-cooled units (no large condenser coils/fans).
Ideal for High-Ambient Areas: Performance remains stable in hot environments where air-cooled systems struggle.
24/7 Industrial Durability: Robust construction for demanding applications and continuous operation.
Advanced Control Systems: Integrated controllers for optimization, monitoring, and diagnostics (Optional: Add specifics like remote access).